Hi,
I am facing the below issue
Starting Analysis applications in BI Launchpad or in the Designer
via "Execute on BI Platform" leads to invalid URLs like
http://***** or http://%2A%2A%2A%2A%2A%2A%2A/.
I tried the following as per note[1894504] but get the same blank page.
This issue will be fixed with BI Platform service pack 06.
WORKAROUND: change the OpenDocument URL in CMC (Choose Applications => Open Document => Context menu "Process Settings". In case this URL
already looks corrupted (http://*****) please enter the URL of the following format and replace the 2 variables with the correct values:
http://< boe-server>:<boe-http-port>/BOE/OpenDocument/opendoc/openDocument.jsp?sIDType=CUID&iDocID=%SI_CUID%
In case this URL looks correct you must at least change 1 char and then press OK otherwise the OK button has no effect. In a 2nd step open
the settings again and undo the previous change. Now you can test with the Designer and the "Execute on BI Platform" menu item.
Please help.
Thanks,
Rajiv